SECTION 4.0: SERIAL COMMUNICATIONS
4.1 HART COMMUNICATIONS
The HART Communications Protocol (Highway Addressable Remote Transducer Protocol) is a
bidirectional digital serial communications protocol. The HART signal is based on the Bell 202
standard and is superimposed on 4-20 mA Output 1. Peer-to-peer (analog / digital) and multi-drop
(digital only) modes are supported.
4.1.1 WIRING
The diagrams below detail the proper connections required for HART communications:
Loop Powered Meter Wiring
LOOP
POWER
+ -
FREQ
OUT
PULSE
OUT
-- + +
OPTIONAL
BACKLIGHT
POWER
+ -
R load,
250 ohm
minimum
+
_
DC
Power
Supply
Remote Connection
for Communicator
Current
Meter
Field Connection
for Communicator
Vortex Meter
Figure 50. Loop Powered Meter Wiring (HART)
WARNING
Place controls in manual mode when making conguration changes to the vortex meter.